Water-Based Systems Layout I (105 questions) VERSION B
Results
#1. What type of testing requires the use of a refractometer?
#2. Double Check Valve Assembly
#3. During testing of a diesel engine driven fire pump system, the fire pump is running at a low RPM. This is considered a ________?
#4. The gauge on the quick opening device shall indicate _____ as compared to the gauge on the system side of the dry pipe valve?
#5. ITM
#6. What should be included on the list of fire sprinklers required at the spare sprinkler head box?
#7. Monitor Nozzle
#8. At what point on the antifreeze system should the test sample be taken?
#9. When should antifreeze systems be tested?
#10. What chapter outlines the General requirements of NFPA 25?
#11. Bladder Tank Proportioner
#12. NFPA 25 chapter 15 outlines the procedure to follow for impairment of a water based system. Besides this code requirement, what other action shall be followed based on the impairment?
#13. Which of the following is identified as the OSHA control of energy source standard?
#14. What is the minimum width allowed for the ladder stairs?
#15. Sprinklers are subject to overspray accumulation shall be protected using cellophane bags having a thickness of ______ inches?
#16. At what pressure & test time duration are FDC connections required to be hydrostatically tested?
#17. When should the vortex plate on a water storage tank be visually inspected?
#18. Alarm Receiving Facility
#19. At what time interval(s) should water storage tank level indicators be tested for accuracy?
#20. What type of antifreeze solution should be utilized in CPVC piping?
#21. What is a purpose of a control valve?
#22. A class 1 standpipe system is a system that provides _______ in hose connections to water supply used by fire departments
#23. In Line Balanced Pressure Proportioner
#24. During an inspection, which of the following would be identified as a sprinkler which shall be replaced?
#25. Which of the following signs require a quarterly inspection to verify that it is securely attached to the sprinkler riser?
#26. Rebuild
#27. Sprinklers shall be tested for sensitivity and functionality at ______ PSI
#28. Control Mode Specific Application (CMSA) Sprinkler
#29. Name six signs of a fire sprinkler that would require replacement
#30. What type of valve is designed for the purpose of reducing downstream water pressure under both residual and static conditions?
#31. Are alternative nondestructive examination methods for internal obstructive inspections permitted?
#32. When are hard hats required on the job sites?
#33. Which Chapter covers the minimum requirements of Standpipe & Hose Systems?
#34. Which of the following is required for locks and tags used in a lockout/ tagout procedure?
#35. What is the definition of AHJ?
#36. Adjust
#37. Hearing protection is required when the noise level reaches 90 DBA for a duration of ____ hrs?
#38. Hose Nozzle
#39. Is a fire department connection required to be hydrostatically tested?
#40. Sectional Drain
#41. Performance Based Program
#42. Corrosion Resistant Sprinkler
#43. At what minimum points or locations should internal obstructive examinations be performed?
#44. All penetrations into the area of cold storage shall be inspected. If an ice obstruction is found during the inspection, what requirement shall be employed?
#45. Dry pipe systems are allowed to be kept wet during non-freezing weather under what circumstances?
#46. Standard Pressure Proportioner
#47. Wet Barrel Hydrant
#48. Deficiency
#49. What is the minimum time that a fire hydrant should be flowed?
#50. Response Time Index (RTI)
#51. Authority Having Jurisdiction (AHJ)
#52. Equipment should be locked out/ tagged out when which of the following conditions exist?
#53. Automatic Operation
#54. Hose Station
#55. Normally closed valves shall be secured by the means of a seal or, be ________ in accordance with the applicable NFPA standard
#56. Pressure Restricting Device
#57. At what interval should a steel water storage tank with no corrosion protection be visually inspected internally?
#58. What is the frequency for testing the hose connections for pressure reducing and relief valves?
#59. [Foam] Discharge Device
#60. At what interval should the interior of water storage tanks be visually inspected if constructed of steel with a corrosion barrier or of other approved/listed material?
#61. At what frequency should vane type and pressure type water flow devices be tested?
#62. Maintenance
#63. What is Table 6.1.1.2?
#64. Internal examination of sprinkler pipe shall be performed at what areas while conducting an obstruction investigation and prevention?
#65. Define hydrostatic test
#66. When using a grounded power tool you find an available extension cord (2-wire). What should you do?
#67. When should an antifreeze system be tested at more than one point?
#68. Preplanned Impairment
#69. ITM Service
#70. Sidewall Sprinkler
#71. Are buildings with multiple wet pipe systems required to have all systems internally inspected at the same time?
#72. Qualified
#73. Repair
#74. Sprinklers installed in areas that are inaccessible for safety considerations, due to process operations ____ be ____ during each scheduled shutdown?
#75. What specialized equipment is needed to test waterflow alarm devices on a wet pipe system?
#76. Which of the following would be an acceptable material for the information sign to be made of?
#77. From what position or level should fire sprinkler piping, fittings, and sprinkler heads be visually inspected?
#78. Pressure Regulating Device
#79. Pressure Vacuum Vent
#80. Where can the referenced publications that are used to create NFPA 25 be found?
#81. Water Spray Nozzle
#82. Dry Barrel Hydrant (Frostproof)
#83. Name the system that utilizes a plate through which passes a specific amount of foam concentrate at a specific pressure
#84. On what type of systems can possible ice obstructions be found?
#85. What types of impairments are defined in NFPA 25?
#86. Are dry barrel hydrants required to be pumped out after flow testing?
#87. Sprinklers subject to overspray accumulation shall be protected by using?
#88. Some water storage tanks are equipped with heaters
#89. Emergency Impairment
#90. What is the frequency & purpose of testing fire hydrants?
#91. What are the inspection requirements for hangers and seismic braces installed in concealed spaces?
#92. Clean
#93. NFPA
#94. Horizontal Rack
#95. How often shall the system information sign be tested?
#96. Line Proportioner
#97. Fire Department Connection
#98. When is the proper time for the employee’s to receive training on the company fall arrest system?
#99. Inspection
#100. Hose connections should be inspected, tested, and maintained in accordance with NFPA 25 Chapter ______ and Chapter____?
#101. What is the maximum full drainage time for a fire hydrant?
#102. I need a False
#103. Concealed Sprinkler
#104. Listed
#105. At what minimum interval should exposed pipe, fittings, and sprinkler heads be visually inspected?