Water-Based Systems Layout I (105 questions) VERSION B
Results
#1. Identify what type of sprinkler is designed to be installed in such a way that the water stream is directed downward against the deflector?
#2. Fire Hydrant
#3. What type of valve is designed for the purpose of reducing downstream water pressure under both residual and static conditions?
#4. When should a flow test be performed on a Class 1 standpipe system?
#5. Replace
#6. Deficiency
#7. Approved
#8. Wet Barrel Hydrant
#9. What is the maximum full drainage time for a fire hydrant?
#10. Noncritical Deficiency
#11. Gauges not accurate to within _______ percent of the full scale shall be recalibrated or replaced?
#12. Which of the following signs require a quarterly inspection to verify that it is securely attached to the sprinkler riser?
#13. Which Chapter covers the minimum requirements of Standpipe & Hose Systems?
#14. From what position or level should fire sprinkler piping, fittings, and sprinkler heads be visually inspected?
#15. Hydrostatic Test
#16. What is the frequency & purpose of testing fire hydrants?
#17. Remove
#18. At what minimum points or locations should internal obstructive examinations be performed?
#19. At what point on the antifreeze system should the test sample be taken?
#20. Is a fire department connection required to be hydrostatically tested?
#21. Normally closed valves shall be secured by the means of a seal or, be ________ in accordance with the applicable NFPA standard
#22. Automatic Detection Equipment
#23. What is Table 6.1.1.2?
#24. ITM Service
#25. What is the pressure for hydrostatic testing of standpipes & hose systems?
#26. Alarm Receiving Facility
#27. What is the minimum width allowed for the ladder stairs?
#28. During an inspection, which of the following would be identified as a sprinkler which shall be replaced?
#29. Automatic Operation
#30. Pendent Sprinkler
#31. Pressure Restricting Device
#32. Hose Nozzle
#33. When should more than one test point be required on an antifreeze system?
#34. Define hydrostatic test
#35. Hose Connection
#36. Sectional Drain
#37. Internal examination of sprinkler pipe shall be performed at what areas while conducting an obstruction investigation and prevention?
#38. When should an antifreeze system be tested at more than one point?
#39. [Foam] Discharge Device
#40. Shall
#41. What chapter outlines the General requirements of NFPA 25?
#42. What table references the required action whenever a component in a fire sprinkler system is adjusted, repaired, reconditioned, or replaced?
#43. Control Mode Specific Application (CMSA) Sprinkler
#44. In systems where the sole water supply is through a backflow preventer and/or pressure reducing valves, the main drain test of at least one system downstream of the device shall be conducted ________?
#45. Name six signs of a fire sprinkler that would require replacement
#46. NFPA
#47. What is the maximum allowed scissor lift speed?
#48. When should antifreeze systems be tested?
#49. When test results show that the premix antifreeze solution is at the incorrect freeze point, what action shall be taken?
#50. At what interval should a steel water storage tank with no corrosion protection be visually inspected internally?
#51. Foam Concentrate
#52. At what frequency should vane type and pressure type water flow devices be tested?
#53. Standard Pressure Proportioner
#54. What type of precautions should shall take place prior to entering confined spaces such as tanks, valve pits, or trenches?
#55. Dry Barrel Hydrant (Frostproof)
#56. Are buildings with multiple wet pipe systems required to have all systems internally inspected at the same time?
#57. Rebuild
#58. Pressure Regulating Device
#59. Sprinklers subject to overspray accumulation shall be protected by using?
#60. Is nonmetallic piping required to be internally inspected for the presence of foreign organic or inorganic matter?
#61. What is a purpose of a control valve?
#62. Main Drain
#63. Hose House
#64. What chapter of NFPA 25 sets out the administration or scope?
#65. Automatic Transfer Switch
#66. At what pressure & test time duration are FDC connections required to be hydrostatically tested?
#67. Gauges shall be replaced every ____ yrs or tested every ____ yrs by comparison with a calibrated gauge
#68. What types of impairments are defined in NFPA 25?
#69. Conventional Pin Rack
#70. When there is a _________ percent reduction in full flow pressure, when compared to original acceptance test, the cause of the reduction shall be identified and corrected
#71. Maintenance
#72. Recessed Sprinkler
#73. Inspection
#74. Corrosion Resistant Sprinkler
#75. How far above the point of support is a ladder required to extend when used to access the roof ____ ft
#76. Monitor Nozzle Hydrant
#77. Clean
#78. In Line Balanced Pressure Proportioner
#79. Hose connections should be inspected, tested, and maintained in accordance with NFPA 25 Chapter ______ and Chapter____?
#80. Flush Sprinkler
#81. Repair
#82. Listed
#83. Standard
#84. What is the definition of AHJ?
#85. Double Check Valve Assembly
#86. Are alternative nondestructive examination methods for internal obstructive inspections permitted?
#87. Where can the referenced publications that are used to create NFPA 25 be found?
#88. Adjust
#89. On what type of systems can possible ice obstructions be found?
#90. Standard Balance Pressure Proportioner
#91. When is the proper time for the employee’s to receive training on the company fall arrest system?
#92. What type of test shall be provided when a valve is returned to service to determine that the valve is open?
#93. What type of testing requires the use of a refractometer?
#94. Are fire hydrants required to be lubricated?
#95. NFPA 25 chapter 15 outlines the procedure to follow for impairment of a water based system. Besides this code requirement, what other action shall be followed based on the impairment?
#96. Semiautomatic Hose Rack Assembly
#97. During testing of a diesel engine driven fire pump system, the fire pump is running at a low RPM. This is considered a ________?
#98. Orifice Plate Proportioning
#99. Sidewall Sprinkler
#100. At what minimum interval should exposed pipe, fittings, and sprinkler heads be visually inspected?
#101. I need a False
#102. Upright Sprinkler
#103. Emergency Impairment
#104. When should components of standpipe and hose systems be visually inspected?
#105. When should a hydrostatic test on a standpipe and/or hose system be performed?