Water-Based Systems Layout I (105 questions) VERSION B

 

Results

#1. At what minimum points or locations should internal obstructive examinations be performed?

#2. A class 1 standpipe system is a system that provides _______ in hose connections to water supply used by fire departments

#3. Pressure Restricting Device

#4. Name six signs of a fire sprinkler that would require replacement

#5. Hose Station

#6. What type of antifreeze solution should be utilized in CPVC piping?

#7. Which Chapter covers the minimum requirements of Standpipe & Hose Systems?

#8. Automatic Detection Equipment

#9. Corrosion Resistant Sprinkler

#10. At what pressure & test time duration are FDC connections required to be hydrostatically tested?

#11. Impairment

#12. When can existing fire hoses be removed from service and not be listed as a deficiency?

#13. Which of the following is identified as the OSHA control of energy source standard?

#14. Reduced Pressure Principle Backflow Prevention Assembly (RPBA)

#15. In Line Balanced Pressure Proportioner

#16. Authority Having Jurisdiction (AHJ)

#17. Pressure Regulating Device

#18. Pendent Sprinkler

#19. Main Drain

#20. Manual Operation

#21. What is a purpose of a control valve?

#22. When is the proper time for the employee’s to receive training on the company fall arrest system?

#23. Gauges not accurate to within _______ percent of the full scale shall be recalibrated or replaced?

#24. Where can the referenced publications that are used to create NFPA 25 be found?

#25. At what minimum interval should exposed pipe, fittings, and sprinkler heads be visually inspected?

#26. Hose Connection

#27. Remove

#28. When should antifreeze systems be tested?

#29. Orifice Plate Proportioning

#30. What is a fire service main?

#31. Automatic Transfer Switch

#32. Dry pipe systems are allowed to be kept wet during non-freezing weather under what circumstances?

#33. What type of valve is designed for the purpose of reducing downstream water pressure under both residual and static conditions?

#34. What type of test shall be provided when a valve is returned to service to determine that the valve is open?

#35. At what frequency should vane type and pressure type water flow devices be tested?

#36. Alarm Receiving Facility

#37. An informational sign shall be placed at the _______ supplying the antifreeze loop, dry system, pre-action system, or auxiliary systems control valve

#38. Emergency Impairment

#39. If an explosive actuated tool misfires, you should?

#40. What is Table 6.1.1.2?

#41. Monitor Nozzle

#42. Line Proportioner

#43. Shall

#44. Are buildings with multiple wet pipe systems required to have all systems internally inspected at the same time?

#45. Double Check Valve Assembly

#46. Should

#47. During testing of a diesel engine driven fire pump system, the fire pump is running at a low RPM. This is considered a ________?

#48. Which of the following would be an acceptable material for the information sign to be made of?

#49. Name the system that utilizes a plate through which passes a specific amount of foam concentrate at a specific pressure

#50. ITM Service

#51. At what point on the antifreeze system should the test sample be taken?

#52. Sidewall Sprinkler

#53. Listed

#54. Are fire hydrants required to be lubricated?

#55. Which of the following signs require a quarterly inspection to verify that it is securely attached to the sprinkler riser?

#56. PIV and OS&Y shall be backed al__________ turn from the fully open position to prevent jamming

#57. When are manual wet pipe standpipe systems not required to be hydrostatically tested?

#58. Units

#59. What is the minimum time that a fire hydrant should be flowed?

#60. What type of testing requires the use of a refractometer?

#61. “Shall” Indicates what?

#62. Are dry barrel hydrants required to be pumped out after flow testing?

#63. Rebuild

#64. Approved

#65. Scaffolding and components shall be capable of supporting a weight of?

#66. What portion of the fire department connection is required to be hydrostatically tested?

#67. Wall Hydrant

#68. Noncritical Deficiency

#69. Bladder Tank Proportioner

#70. Replace

#71. Sprinklers shall be tested for sensitivity and functionality at ______ PSI

#72. Concealed Sprinkler

#73. Hearing protection is required when the noise level reaches 90 DBA for a duration of ____ hrs?

#74. When test results show that the premix antifreeze solution is at the incorrect freeze point, what action shall be taken?

#75. How often shall the system information sign be tested?

#76. What components of a fire hydrant are required to be lubricated?

#77. When using a grounded power tool you find an available extension cord (2-wire). What should you do?

#78. Are alternative nondestructive examination methods for internal obstructive inspections permitted?

#79. Standard Pressure Proportioner

#80. When should the vortex plate on a water storage tank be visually inspected?

#81. Performance Based Program

#82. At what time intervals should check valves be internally inspected?

#83. Which of the following is required for locks and tags used in a lockout/ tagout procedure?

#84. Standard

#85. A building has 3 different types of sprinklers. How many sprinkler wrenches are required to be kept on premises?

#86. When are hard hats required on the job sites?

#87. Inspection

#88. What is the frequency for testing the hose connections for pressure reducing and relief valves?

#89. Internal examination of sprinkler pipe shall be performed at what areas while conducting an obstruction investigation and prevention?

#90. What type of device is used to test flow rates?

#91. Some water storage tanks are equipped with heaters

#92. At what interval should a steel water storage tank with no corrosion protection be visually inspected internally?

#93. Foam Concentrate

#94. Repair

#95. Sprinklers installed in areas that are inaccessible for safety considerations, due to process operations ____ be ____ during each scheduled shutdown?

#96. Scope

#97. What chapter outlines the General requirements of NFPA 25?

#98. Normally closed valves shall be secured by the means of a seal or, be ________ in accordance with the applicable NFPA standard

#99. On what type of systems can possible ice obstructions be found?

#100. Response Time Index (RTI)

#101. Automatic Operation

#102. What chapter of NFPA 25 sets out the administration or scope?

#103. At what time interval(s) should water storage tank level indicators be tested for accuracy?

#104. What are the two types of deficiencies identified in NFPA 25?

#105. At what interval should the interior of water storage tanks be visually inspected if constructed of steel with a corrosion barrier or of other approved/listed material?